ATO Solutions provides NICEIC-accredited EICR certificates in Tooting, covering residential and commercial properties across the area. An Electrical Installation Condition Report (EICR) — also known as an electrical safety certificate, or historically as a Periodic Inspection Report (PIR) — is a formal assessment of the fixed electrical installation in your property. It identifies electrical faults and potential hazards such as faulty wiring, overloaded circuits, fire risks, and the risk of electric shock, and results in a detailed written report and certificate confirming whether the installation is safe and compliant.
We are based in nearby Wimbledon, SW19, and have been carrying out EICRs across South West London for over 17 years. Certificates are issued within 3–5 days of the inspection as standard, with a 2-day express option available when turnaround is critical — for example, at the start of a new tenancy.

Local authorities can issue fines of up to £30,000 for non-compliance. If you manage a portfolio of properties in Wimbledon or the wider Merton area, contact us to discuss a scheduled inspection programme.
Why landlords and homeowners in Tooting choose ATO Solutions
- Speak to the electrician, not a middleman. Call ATO and you’re talking to the person who’ll turn up at your door — no call centre, and no form that sells your details on to a nearby contractor.
- One honest, upfront price. The price we quote is the price you pay, with no VAT added at the end. The only possible extra is parking — if there’s no free off-road space at your property and we have to pay to park, we’ll agree that with you on the phone before booking, never spring it on you afterwards.
- An inspection, not a sales pitch. We won’t fail your installation to win the remedial work. If something needs doing, you’ll get a straight explanation and a fair quote — and if it’s all sound, we’ll tell you that too.
- A proper job, not a rushed one. An EICR isn’t a five-minute walk-round. A typical inspection takes 2–3 hours at your property, and the certificate itself takes several hours more to prepare and check before it reaches you. It’s a legal document your insurer, local authority, letting agent, tenant or buyer may all rely on — so we take the time to get it right rather than rush something that could cause you problems later.
- A report you can actually use. A fully certified EICR you can hand straight to your letting agent, buyer, insurer or tenant.
- Fast turnaround. Certificate issued within 3–5 working days.
- Local and qualified. A fully qualified electrician covering Tooting and the surrounding SW postcodes.
Who Needs an EICR in Tooting?
Landlords
Since July 2020, all private landlords in England — including those letting properties in Tooting — must hold a valid EICR for every tenanted property. Under the electrical safety regulations governing the private rented sector, EICRs must be renewed every five years, or at every change of tenancy if sooner, and a copy must be provided to tenants. Tooting is one of South West London’s busiest rental markets, with high demand from young professionals and families, and the London Borough of Wandsworth actively enforces electrical safety compliance — landlords without a current certificate risk fines of up to £30,000.
Homeowners
For homeowners, an EICR is recommended every ten years, or when buying or selling a property. Much of Tooting’s housing stock consists of Victorian and Edwardian terraces, many of which have older wiring and consumer units that no longer meet current standards. If you own a Tooting property that has not had an electrical inspection in recent years, an EICR is strongly recommended — and it is commonly requested by conveyancers and mortgage lenders as part of a home purchase.
Commercial Properties
Commercial buildings and premises in Tooting — including the many shops, cafes, and restaurants along Tooting High Street and Mitcham Road — should have an EICR carried out every five years as standard, and many insurers require a current certificate as a condition of cover. Our expertise covers both residential and commercial properties, so business owners get the same thorough service and detailed report as domestic clients.
What Does the Inspection Cover?
During the inspection, a qualified NICEIC-accredited engineer carries out a detailed visual inspection followed by a series of electrical tests, all in line with the current IET Wiring Regulations (BS 7671, the British Standard for electrical installations), assessing the condition of:
- The consumer unit (fuse board) and its protective devices
- All fixed wiring and electrical circuits throughout the property
- Sockets, switches, and light fittings
- Earthing and bonding arrangements
- Smoke alarms, fire alarms, and emergency lighting where connected to the fixed installation
- Any previous electrical work or alterations
Any issues are recorded using a standardised coding system. A C1 indicates danger present, requiring immediate remedial action. A C2 indicates a potentially dangerous condition requiring urgent remedial action. A C3 is a recommendation for improvement. An FI code means further investigation is required. The overall outcome is either Satisfactory or Unsatisfactory. For a full breakdown of the process and codes, see our EICR page.

Who Can Carry Out an EICR in Tooting?
An EICR must be carried out by a qualified, competent person — someone with the training, experience, and calibrated test equipment to inspect and test an electrical installation safely and correctly. As a NICEIC-registered contractor, ATO Solutions is a registered competent person under Part P of the Building Regulations, which means our Tooting EICR testing is fully recognised by letting agents, local authorities, and mortgage lenders.
Every EICR we issue records the date of the inspection and the recommended date for the next inspection, so you know exactly when your certificate is due for renewal. We keep the property details on file, which makes arranging your next EICR straightforward when the time comes.
Is an EICR Required for HMOs in Tooting?
Yes. Houses in Multiple Occupation (HMOs) require an EICR as part of their licensing conditions, and the standards applied are typically more stringent than for standard tenancies. Tooting has one of the highest concentrations of HMO and shared rental properties in the borough, driven by strong demand from young professionals and proximity to St George’s Hospital and the transport links. If you operate an HMO in Tooting, contact us to discuss your specific requirements — the inspection scope and reporting may differ from a standard domestic EICR.
EICRs, PAT Testing & Related Certificates
An EICR covers the fixed electrical installation — the wiring, consumer unit, and fixed fittings. It does not cover portable electrical appliances. If you supply appliances with a rental property, such as white goods or a television, these are covered separately by Portable Appliance Testing (PAT testing), which we also provide. Where it suits, we can carry out both together to minimise disruption. See our PAT Testing page for more.
An electrical safety certificate is one of several compliance documents landlords are required to maintain. A gas safety certificate (issued annually by a Gas Safe registered engineer) and an Energy Performance Certificate (EPC) are also required for rental properties. These fall outside our scope as an electrical contractor, but your letting agent or an accredited assessor can arrange them. Keeping all three current forms the basis of a landlord’s regulatory compliance.
Why Choose ATO Solutions?
- NICEIC-accredited — certificates are fully legally recognised and compliant
- Local to Tooting — based in nearby Wimbledon, with fast response and no inflated travel charges
- 17+ years’ experience with landlord and rental property inspections
- Certificates within 3–5 days as standard, or 2-day express service available
- Clear, jargon-free reports — a detailed report written to be understood, not filed away unread
- Competitive fixed pricing from £99, quoted upfront with no hidden charges
- Remedial work available — one contractor for the inspection and any follow-up work
- Minimal disruption — we work efficiently and around your tenants where possible
- Peace of mind — a clear, detailed report and full legal compliance, documented

EICR Pricing for Tooting Properties
All prices are all-inclusive. Certificates are issued within 3–5 days as standard, or within 2 days with our express service. The cost of an EICR varies based on several factors — principally the property type and size, the number of electrical circuits, and the complexity of the installation — so final pricing is confirmed following the inspection.
Call 0800 050 2424 for a quote specific to your Tooting property.
| Property Type | Guide Price (no VAT) |
| Studio / 1 bedroom flat | £99 – £130 |
| 2 bedroom property | £130 – £180 |
| 3 bedroom property | £150 – £230 |
| 4 bedroom property | £180 – £250 |
| 5+ bedroom property | £250 – £350 |
| Commercial property | £250 – £1,000 (dependent on number of distribution boards and circuits) |
Frequently Asked Questions
Frequently Asked Questions
Do you carry out EICRs across the whole of Tooting?
Yes — we cover Tooting and the surrounding areas, including Tooting Broadway, Tooting Bec, Tooting Graveney, and the wider SW17 postcode. We are based in nearby Wimbledon, which means a fast response and no inflated travel costs.
How often do I need an EICR in Tooting?
At least every five years, or at every change of tenancy if that occurs sooner. If a previous report recommended a shorter interval, that recommendation takes precedence. Wandsworth Council can request a copy of your current certificate at any time.
What happens if my property gets an Unsatisfactory result?
An EICR does not technically pass or fail — the outcome is either Satisfactory or Unsatisfactory. If the result is Unsatisfactory due to C1 or C2 findings, you are required to arrange remedial work within 28 days and provide written confirmation to your tenant that the work has been completed. We provide an itemised quote for any remedial work and can carry it out promptly to keep your property compliant.
What electrical faults are most commonly found during an EICR in Tooting?
Common findings — particularly in Tooting’s older Victorian and Edwardian terraces — include faulty or deteriorated wiring, overloaded circuits that cause tripping, inadequate earthing and bonding, and consumer units without RCD protection. Warning signs between inspections can include tripping circuits, scorch marks, or burning smells from a socket or the fuse box, all of which should be checked promptly. Many faults are not visible without a detailed inspection, which is why regular EICRs against current British Standards are important even when a property appears to be functioning normally.
Is an EICR the same as a landlord electrical safety certificate?
Yes. The EICR is the inspection, and the landlord electrical safety certificate is the document it produces. The terms are used interchangeably. See our Landlord Electrical Certificate page for landlord-specific detail.