ATO Solutions provides NICEIC-accredited EICR inspections throughout Putney, covering residential and commercial properties across SW15, from the riverside to Putney Heath and Roehampton. An Electrical Installation Condition Report (EICR) — also known as an electrical safety certificate, or historically as a periodic inspection report — is a formal assessment of the fixed electrical installation in your property. It identifies electrical faults and potential hazards such as faulty wiring, overloaded circuits, fire risks, and the risk of electric shock, and results in a detailed written report confirming whether the installation is safe and compliant.
We are based nearby in Wimbledon, so Putney landlords, letting agents, homeowners, and business owners get prompt appointments, clear fixed pricing, and no inflated travel costs.

Local authorities can issue fines of up to £30,000 for non-compliance. If you manage a portfolio of properties in Merton or the wider Merton area, contact us to discuss a scheduled inspection programme.
EICR Certificates in Putney for Every Type of Property
Landlords & Letting Agents
Putney has a large and fast-moving rental market, from professional lets close to Putney and East Putney stations to student and shared housing near the University of Roehampton. Under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, private landlords must have the electrical installation inspected and tested at least every five years. A copy of the report must be given to existing tenants within 28 days of the inspection, to new tenants before they move in, and to Wandsworth Council within 7 days if requested. Councils can issue fines of up to £30,000 for non-compliance.
With high tenant turnover in the area, keeping certificates current matters. We work with landlords and letting agents across Putney and can arrange access directly with tenants to keep disruption to a minimum. See our Landlord Electrical Certificate page for more detail on your legal obligations.
Homeowners
Putney’s housing is unusually varied. Victorian and Edwardian terraces and conversions fill the streets between the High Street and Upper Richmond Road, alongside mansion blocks, larger period houses towards Putney Heath, post-war estates in Roehampton, and modern riverside apartments. Older homes in particular have often been extended or partially rewired over the decades. For owner-occupiers, an EICR is recommended at least every ten years, and it is commonly requested by conveyancers and mortgage lenders during a home purchase.
Commercial Properties
Commercial premises in Putney — including the shops on Putney High Street and around The Exchange, the restaurants and pubs of Lower Richmond Road, and the clubs and venues along the Embankment — should have an EICR carried out every five years as standard, and many insurers require a current certificate as a condition of cover. Our expertise covers both residential and commercial properties, so business owners get the same thorough inspection and detailed report as domestic clients, scheduled around opening hours where possible.
What Does the Inspection Cover?
During the inspection, a qualified NICEIC-accredited electrician carries out a detailed visual inspection followed by a series of electrical tests, all in line with the current IET Wiring Regulations (BS 7671), assessing the condition of:
- The consumer unit (fuse board) and its protective devices
- All fixed wiring and electrical circuits throughout the property
- Sockets, switches, and light fittings
- Earthing and bonding arrangements
- Smoke alarms and fire alarms where connected to the fixed installation
- Emergency lighting in commercial and HMO properties
- Any previous electrical work or alterations
Any issues are recorded using a standardised coding system. A C1 indicates danger present, requiring immediate remedial action. A C2 indicates a potentially dangerous condition requiring urgent remedial action. A C3 is a recommendation for improvement. An FI code means further investigation is required. The overall outcome is either Satisfactory or Unsatisfactory. For a full breakdown of the process and codes, see our EICR page.


Who Can Carry Out an EICR in Putney?
An EICR must be carried out by a qualified, competent person — someone with the training, experience, and calibrated test equipment to inspect and test an electrical installation safely and correctly. As a NICEIC-registered contractor, ATO Solutions is a registered competent person under Part P of the Building Regulations, which means our Putney EICR testing is fully recognised by letting agents, local authorities, and mortgage lenders.
Every EICR we issue records the date of the inspection and the recommended date for the next inspection, so you know exactly when your certificate is due for renewal. We keep the property details on file, which makes arranging your next EICR straightforward when the time comes.
Is an EICR Required for HMOs in Putney?
Yes. Houses in Multiple Occupation (HMOs) require a valid EICR as part of their licensing conditions, and the standards applied are typically more stringent than for standard tenancies. Shared houses in Putney and Roehampton, including student lets, often fall under mandatory HMO licensing, which applies where five or more people from two or more households share facilities. Check with Wandsworth Council whether any additional licensing scheme applies to your property.
HMO inspections commonly include fire alarm systems and emergency lighting where fitted, as well as the fixed wiring in each let room and the shared areas. We carry out HMO EICRs throughout Putney and can provide the documentation your licence application or renewal requires.
EICRs, PAT Testing & Related Certificates
An EICR covers the fixed electrical installation — the wiring, consumer unit, and fixed fittings. It does not cover portable electrical appliances. If you supply appliances with a rental property, such as white goods or a television, these are covered separately by Portable Appliance Testing (PAT testing), which we also provide. Where it suits, we can carry out both together to minimise disruption. See our PAT Testing page for more.
An electrical safety certificate is one of several compliance documents landlords are required to maintain. A gas safety certificate (issued annually by a Gas Safe registered engineer) and an Energy Performance Certificate (EPC) are also required for rental properties. These fall outside our scope as an electrical contractor, but your letting agent or an accredited assessor can arrange them.
Why Choose ATO Solutions for Your Putney EICR?
- NICEIC accredited — every inspection carried out and certified by a qualified, registered electrician
- 30+ years’ experience — led by Barry, an electrician since 1994
- Local to Putney — based in Wimbledon SW19, a short drive across the Common
- Clear, fixed pricing — quoted upfront, with no hidden extras
- Minimal disruption — we work efficiently and around your tenants where possible
- Peace of mind — a clear, detailed report and full legal compliance, documented

All prices are all-inclusive. EICR certificates are issued within 3–5 days as standard, or within 2 days with our express service. The cost of an EICR varies based on several factors — principally the property type and size, the number of electrical circuits, and the complexity of the installation — so final pricing is confirmed following the inspection.
How Much Does an EICR Cost in Putney?
- Studio / 1 bedroom flat — £99 to £130
- 2 bedroom property — £130 to £180
- 3 bedroom property — £150 to £230
- 4 bedroom property — £180 to £250
- 5+ bedroom property — £250 to £350
- Commercial property — £250 to £1,000 depending on the number of distribution boards and circuits
Call 07714 281 781 for a quote specific to your Putney property.
Frequently Asked Questions
Frequently Asked Questions
Do you carry out EICRs across the whole of Putney?
Yes — we cover the whole SW15 postcode, including East Putney, West Putney, Putney Heath, and Roehampton, as well as neighbouring Southfields and Earlsfield. We also cover the wider Wandsworth borough and nearby Wimbledon.
Do new-build and modern apartments need an EICR?
Yes, if they are rented. The five-year requirement applies to all private rented properties, regardless of age. A newer installation will typically be quicker to inspect, but the landlord still needs a current report. For owner-occupied new builds, the original electrical installation certificate covers the first few years, and an EICR is recommended after that.
How often do I need an EICR in Putney?
For rented properties, at least every five years. If a previous report recommended a shorter interval, that recommendation takes precedence. Wandsworth Council can request a copy of your current report at any time. For owner-occupied homes, every ten years is recommended.
What happens if my property gets an Unsatisfactory result?
An EICR does not technically pass or fail — the outcome is either Satisfactory or Unsatisfactory. If the result is Unsatisfactory due to C1, C2, or FI findings, landlords must arrange remedial work or further investigation within 28 days, or sooner if the report specifies. Written confirmation that the work is complete must then be given to the tenant and to Wandsworth Council within 28 days of completion. We provide an itemised quote for any remedial work and can carry it out promptly to keep your property compliant.
What electrical faults are most commonly found during an EICR in Putney?
In Putney’s older period homes and conversions, common findings include deteriorated wiring, overloaded circuits, inadequate earthing and bonding, and consumer units without RCD protection. Flats converted from larger houses can show mixed standards where circuits have been altered over the years. Many of these issues can present a fire or electric shock risk and are not visible without a detailed inspection.
Is an EICR the same as a landlord electrical safety certificate?
Yes. The EICR is the inspection, and the landlord electrical safety certificate is the document it produces. The terms are used interchangeably. See our Landlord Electrical Certificate page for landlord-specific detail.
Areas We Cover
We are based in Wimbledon and cover the entire London Borough of Merton: Wimbledon (SW19/SW20), Raynes Park (SW20), Morden (SM4), Mitcham (CR4), Colliers Wood (SW19), and South Wimbledon (SW19). We also cover neighbouring boroughs including Wandsworth, Sutton, Kingston, and Lambeth — so if your property portfolio spans borough boundaries, we can cover it all.